AV ComfyUI Manual
51 / 64
Files
51
NODES 543 / 715

Widget value ≠ effective runtime value

Shared PPL selector 543 distributes one control INT to several image switches. The number displayed inside a child selector may therefore be only a stored widget value, not the active runtime value.

CONFIRMEDControl links and values verified against workflow topology
LINKED CONTROL TREE

543 = 1 drives four switches

NODE 5431 = FLUXshared INT control
459FLUX composite #672→ return 573
522raw SAM mask #524→ preview 508
552PPL FLUX #829→ resize 780 / crop 503
715 · RETURN / DOWNSTREAMoutputs BASE #79→ image2 of 552 · ignored now
NESTED SWITCH

In mode 1, node 552 selects its own image1 #829, so output 715 does not participate. In mode 2, both switches select their second input and 715 passes SDXL decode #14 into 552.

01 · NODE 543

One control drives four selectors

Node 543 is titled SWITCH PPL: 1=FLUX / 2=INPUT and currently equals 1. Its output is connected to the control input of nodes 459, 522, 552 and 715.

SelectorStored widgetLinked controlEffective now
459 · PPL Switch1543 = 1FLUX composite
522 · People Input Switch1543 = 1FLUX mask/inpaint source
552 · People Input Switch1543 = 1FLUX-generated input
715 · Return / Downstream source selector2543 = 1Outputs BASE #79, but 552 currently ignores this input
02 · NODE 715

Why “2” inside node 715 does not mean mode 2

715 is a CR Image Input Switch titled “People Input Switch 1=FLUX / 2=3D rendered”. Its image1 comes from BASE IMAGE 79, image2 from SDXL VAEDecode 14, and its output feeds image2 of node 552. The widget stores 2, but control Input is linked to node 543.

With current 543 = 1, node 715 outputs #79, while node 552 simultaneously chooses its own image1 = PPL FLUX #829. The output of 715 therefore does not enter the current production path. In this manual, 715 is labeled Return / Downstream Selector — a functional label for nested downstream source selection, not an independent final composite.

CONFIRMED

Current effective control

543 = 1 makes 715 select BASE #79, but downstream 552 selects #829 and ignores output 715.

CONFIRMED

Downstream

Node 715 output is connected to an input of node 552.

INFERRED

Nested-switch nuance

The #79 → 715 → 552 branch is unreachable under the normal 1/2 states: at 1, 552 ignores it; at 2, 715 itself selects #14.

03 · SAFE SWITCHING

Change PPL mode at node 543

  • 1 — use the FLUX-generated people branch.
  • 2 — use the INPUT / 3D-rendered people branch.
  • Do not manually align widgets 459/522/552/715 while their control input remains linked to 543.
  • After changing mode, verify not only generation preview but also output node 459.
04 · TRUTH TABLE

543 × 693 × 715: which source is actually selected

CONFIRMED

Linked override

Stored widget 2 inside node 715 does not select mode 2 while Input is linked to node 543=1.

NOT CONFIRMED

3D source semantics

Topology does not expose a dedicated LoadImage that proves the origin of the source labelled 3D rendered.

543693715 effective552 source459 return
1 · FLUX1 · resized1PPL FLUX decode 829First composite 672
1 · FLUX2 · original1PPL FLUX decode 829First composite 672
2 · INPUT1 · resized2715 selected input, then component inpaintResized return 685
2 · INPUT2 · original2715 selected input, then component inpaintOriginal-canvas return 685